[av_textblock fold_type=” fold_height=” fold_more=’Devamını Oku’ fold_less=’Read less’ fold_text_style=” fold_btn_align=” textblock_styling_align=” textblock_styling=” textblock_styling_gap=” textblock_styling_mobile=” size=” av-desktop-font-size=” av-medium-font-size=” av-small-font-size=” av-mini-font-size=” font_color=” color=” fold_overlay_color=” fold_text_color=” fold_btn_color=’light’ fold_btn_bg_color=” fold_btn_font_color=” size-btn-text=” av-desktop-font-size-btn-text=” av-medium-font-size-btn-text=” av-small-font-size-btn-text=” av-mini-font-size-btn-text=” fold_timer=” z_index_fold=” id=” custom_class=” template_class=” av_uid=’av-lk7ximb1′ sc_version=’1.0′ admin_preview_bg=”]
THREE PHASE RECTIFIER (3 PHASE)
Three Phase Rectifiers are three phase input thyristor module rectifier type. It is the ideal solution for quality DC signals in small and medium-sized enterprises. Depending on the desired ripple level, the LC filter can be added. It can also be used as battery charger for charging purposes.
For output signal quality, 6 pulses, 12 pulses and 18 pulses can be produced. Thanks to the 12 pulse and 18 pulse applications, the THD value is reduced and the cosQ value is kept around 0.9
Thanks to 2×16 LCD screen, output voltage, output current, input voltage, frequency and fault status information can be monitored. 100 past fault information can be accessed.
Microprocessor controlled. With RS232, 0-10VDC or 4-20 mA signal, modbus and dry contact, the user is informed about the operating status of the device. It has the possibility of adjusting current and voltage.
It can be used with battery in continuous DC source applications. With the low protection unit, the battery is prevented from being discharged to the end of the discharge. The solution is produced by using a dropper diode where output voltage sensitivities are present.
It can be carried easily with its wheels. In addition, there are aesthetic base models with fixing suitable for panel rooms.With its isolated transformer and thyristor structure, it is suitable to work under very heavy conditions and the risk of failure is close to zero. The warranty period is 3 years.
You may be interested in:
Related Products
Featured Products
Three Phase Rectifier / Battery Charger Product Gallery
Click to enlarge three-phase battery charger.
- Input Isolation Transformer
- L-C Filter
- Microprocessor controlled
- Thyristor-thyristor Module Structure
- Soft start opening
- 4X20 Line LCD
- EMI filter
- Equalizing charging, Float charging, Boost Charging options
- 6 pulses, 12 pulses, 18 pulses options (for good quality DC beacon)
- Ability to use as current source and voltage source
- 12 / 24V / 48V / 110V / 220V / 500VDC production options
- Production in the range of 10A – 1,000ADC.
- Choice of automatic or manual charging modes
- IU0U charging characteristic
- Output voltage sensitivity with Dropper diode
- Remote control
- Battery monitoring, low battery information and protection in case of mains failure
PROTECTION
- Over Current (electronic)
- Short circuit (electronic)
- Semiconductor Extreme Heat
- Transformer extreme heat
- DC high (electronic)
- DC Low (electronic)
- Mains high (electronic)
- Entry insurance
INDICATORS
- 4×20 Line LCD display
- Input voltage, output voltage, output current, error information tracking
- Indicator language selection (English, Turkish)
- Led status notification
- Analog voltmeter and Analog ammeter can be added.
LINKS
- Input terminal
- DC output terminal block
ARTSAN RECTIFIER GENERAL TECHNICAL SPECIFICATIONS |
|
INPUT | |
Input Voltage | 220 V Or 3×380 V AC |
Input Frequency | 50 Hz |
Input Current | . |
Input Tolerance | -%20, +%15 |
Efficiency | > % 80 |
Power factor | 0.8 < |
OUTPUT | |
Output Voltage | 12V / 24V / 48V / 96V / 110V DC Options Available |
Output Current | 15 A / 30 A / 50 A / 80 A / 100 A / 200 A / 500 A Options Available |
Dynamic Answer | 0 to 100% Max. Voltage change <5% |
Soft Start | 10 Sn. |
Control Type | PWM Controlled Thyristor – Diode Module group |
Trigger Frequency | 3 kHz |
Filter | L-C Filter |
Ripple | 3% |
INDICATORS | |
LCD | 2x 16 LCD display with working status monitoring |
Buttons | Menu monitoring with the help of buttons |
Battery level LEDS | ( %25, %50, %75, %100)* |
Warning leds | Input present, Output present, Over current, Over heat, Battery low, Voltage high |
PROTECTION | |
DC high, DC low (battery low.), Over heat, over current, short circuit, fuses, Earth leakage relay * | |
GENERAL | |
On – Off | Pako Switch |
Montage Type | Floor montage,wall montage,wheeled* |
Warning Contacts | Optional |
Recovery Diod | Standart |
Link | Terminals |
Protection type | IP20 |
Working Temperature | 0 C and 40 C , maximum % 90 |
Noise Level | < 45 DBA |
Cooling | Fan ve Forced |
Device color | RAL7035 |
Emergency lighting units
Telephone exchange
Control Devices
Alarm Systems
Electronic Test Equipment
Radio & TV Stations
Marine Equipment
Fire and Security Systems
Galvanized coating applications
Solution
Technical support
Corporate
Contact
Tags: three phase rectifiers, 3 phase rectifiers, three phase battery charger rectifier, battery charger rectifiers, battery charger,
[/av_textblock]